Generator Model | GJP220 | |
Standby | kVA | 220 |
kW | 176 | |
Prime | kVA | 200 |
kW | 160 | |
Engine Speed | r.p.m | 1500 |
Voltage | V | 230/400 |
Power Factor | Cos Phi | 0,8 |
Model | 1106A-70TAG4 | |
Net Motor Output Power | kW | 174 |
Standby Output Power | kW | 191 |
Brand | Perkins | |
Engine Type | 4 Stroke - Diesel | |
Spray Type | Direct Injection | |
Suction Type | Turbo Charge | |
Number of Cylinders | 6 | |
Bore and Stroke | mm | 105x135 |
Cylinder Volume | L | 7,01 |
Cooling Type | Water Cooled | |
Compression Ratio | 16:01 | |
Fuel Consumption at Stand by Load | l/h | 49,4 |
100% Prime Load Fuel Consumption | l/h | 45,8 |
75% Fuel Consumption at Prime Load | l/h | 34,7 |
50% Fuel Consumption at Prime Load | l/h | 23,1 |
Total Oil Capacity | L | 18 |
Total Cooling Capacity | L | 21 |
Governor Type | Type | Electronics |
Model | M220 | |
Brand | Maranello | |
Output Voltage | V | 230/400 |
Frequency | HZ | 50 |
Automatic Voltage Regulation | ±% | 1 |
Alternator Standby Power | kVA | 220 |
Alternator Prime Power | kVA | 200 |
Power Factor | Cosq | 0,8 |
Number of Cables | 12 | |
Winding Pitch | 2/3 | |
Protection Class | IP23/H | |
Warning System | Self-excited | |
AVR Model | SX460 | |
Performance - PF 0.8 / 75% Load | % | 93,3 |
Dimensions (Open Set) | ||
LxWxH | mm | 2600x1100x1940 |
Weight | kg | 1750 |
Fuel Tank | lt | 360 |
Dimensions (With Cabin) | ||
LxWxH | mm | 3500x1100x2240 |
Weight | kg | 2100 |
Fuel Tank | lt | 360 |